  page 1 of 5 ac/dc power modules tmm 40 series, 40 watt order code output power max. output 1 output 2 effciency pcb mount chassis mount tmm 40105 tmm 40105c 40 w 5.0 vdc / 8000 ma 81 % tmm 40112 tmm 40112c 12 vdc / 3330 ma 84 % tmm 40115 tmm 40115c 15 vdc / 2660 ma 85 % tmm 40124 tmm 40124c 24 vdc / 1660 ma 84 % tmm 40212 tmm 40212c +12 vdc / 1660 ma C12 vdc / 1660 ma 84 % tmm 40215 tmm 40215c +15 vdc / 1330 ma C15 vdc / 1330 ma 85 % models c b scheme u l 60950 -1 es 60601-1 u l 60950 -1 ul 60601-1 also see: tmm 24 series, 24 watt www.tracopower.com/products/tmm24.pdf tmm 60 series, 60 watt www.tracopower.com/products/tmm60.pdf features fully encapsulated low profle plastic casing in pcb- or chassis mount version 2 x mopp medical safety according to aami/ansi es 60601-1:2005(r) and iec/en 60601-1 3rd edition it and industrial safety according to iec/ul 60950-1 and ul 508 ready to meet erp directive <0.3w no load power consumption -40c start-up temperature safety class ii prepared protection against over-temperature overload and short circuit 3-year product warranty the tmm 40 series of fully encapsulated 40 watt ac/dc power supply mod - ules feature a reinforced/double i/o isolation system according to latest medical safety standards 60601-3 3rd edition for 2 x mopp (means of patient protec - tion). the high effciency and the use of highest grade components make the units suitable for an operating temperature range of C40c to +60c while it goes up to 75c with 50% load derating. emi/emc characteristics and the safety ap - proval package qualify these modules not only for medical devices but also for demanding applications in transportation systems and for equipment in industrial an commercial environment. ul 508 http://www.tracopower.com
page 2 of 5 all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. ac/dc power modules tmm 40 series 40 watt input specifications input voltage ranges C nominal 100 C 240 vac C ac input 85 C 264 vac C dc input 120 C 370 vdc input frequency 47 C 440 hz input current at full load (115 vac / 230 vac nominal input) 5 vdc models: 710 ma / 430 ma typ. other models: 690 ma / 415 ma typ. leakage current 80 a typ. no-load power consumption <0.3 w external input fuse required (recommended value) 3 a slow blow type or characteristic c output specifications voltage set accuracy 2% typ. minimum load no minimum load required regulation C input variation 0.5% typ. C load variation (0-100%) single output models: 1.0 % t y p. dual output models: 2.0% typ. temperature coefficient 0.02 %/k ripple and noise (20 mhz bandwidth) 5.0 vdc model: 1.8% of vout [vp-p] max. other models: 1.3% of vout [vp-p] max. current limitation above 105 % of rated output current. hiccup, auto recovery overvoltage protection by zehner diode (main output only) 120 % of vout typ. short circuit protection continous max. capacitive load 5.0 vdc model: 8000 f 12 vdc model: 3900 f 15 vdc model: 3900 f 24 vdc model: 680 f 12 vdc model: 1500 f (each output) 15 vdc model: 1000 f (each output) http://www.tracopower.com
page 3 of 5 ac/dc power modules tmm 40 series 40 watt all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. general specifications temperature ranges C operating (natural convection cooling 20 lfm) C40c to +80c C power derating above +60c 3.75 %/k C storage (non operating) C40c to +95c over temperature protection shutdown: at 90c automatic recovery: at approx 67c humidity (non condensing) 95 % rel max. altitude during operation 5000 m switching frequency (pulse width modulation pwm) 130 khz typ. hold-up time 115 v a c : 25 ms typ. 230 vac: 80 ms typ. isolation voltage C input/output 4000 vac isolation resistance C at 500 vdc 1000 mohm reliability /calculated mtbf (mil-hdbk-217f, at +25c, ground benign) >200000 h emi / rfi conducted and radiated en 55022, class b, fcc part 15, level b en 55011 class b electromagnets compatibility C electrostatic discharge esd iec / en 61000-4-2, 8kv/4kv perf. criteria a (emc), immunity C rf field immunity iec / en 61000-4-3, 10v/m perf. criteria a C electrical fast transients/burst immunity iec / en 61000-4-4, 2kv perf. criteria a C surge iec / en 61000-4-5, 1kv perf. criteria a C conducted rf iec / en 61000-4-6, 10 vr.m.s perf. criteria a C magnetic field immunity iec / en 61000-4-8, 30 a/m perf. criteria a C voltage dip and interruptions (115 vac / 60 hz) iec / en 61000-4-11 30%,10ms perf. criteria a iec / en 61000-4-11 60%,10ms perf. criteria a iec / en 61000-4-11 95%, 5s perf. criteria b protection class ii acording iec/en 60536 safety standards ul 60950-1, iec/en 60950-1, iec/en 60601-1 3rd edition, 2 x mopp a n si/a a m i es60601-1:20 05 ( r ) 2012 ul 508 for chassis mount version C certification documents www.tracopower.com/overview/tmm40 casing material plastic resin (ul 94v-0 rated) environmental compliance C reach www.tracopower.com/overview/tmm40 C rohs rohs directive 2011/65/eu http://www.tracopower.com
page 4 of 5 ac/dc power modules tmm 40 series 40 watt all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. order code for models tmp-mk2 tmm 40xxxc din-rail mounting kit adapter for mounting on din-rails as per en 50022-35 (snap-on mounting) kit contains interface plate, din-rail clip and necessary screws. din-rail mounting kit http://www.tracopower.com
page 5 of 5 ac/dc power modules tmm 40 series 40 watt outline dimensions tmm 40: for pcb mount: weight: 310 g (10.94 oz ) weight: 320 g ( 11. 2 9 o z ) pin diameter ? 1.0 mm (0.039) 1 2 5 4 6 63.5 31.75 81.3 88.9 (2.50) (1.25) bottom view (3.20) (3.50) 3 7 27.94 (1.10) 12.70 (0.50) 15.24 (0.60) 2 x m4 th d 31.6 (1.24) 3.8 (0.15) 15.9 (0.63) 12.70 (0.50) 15.24 (0.60) 27.94 (1.10) 30.0 0.7 6.0 5.0 (0.03) (0.24) (1.18) (0.20) 5.0 (0.20) 53.3 (2.1) 5 46 37 1 2 t op view 100.0 112.0 (3.94) (4.41) 6.0 (0.24) 63.8 (2.51) 6.9 (0.27) 50.0 (1.97) 4 x ?3.5 92.0 (3.62) 10.0 (0.39) 34.1 (1.34) 5.0 (0.20) 11.8 (0.46) indication led tmm 40c: for chassis mount: nc = not to connect dimensions in[mm], () = inches tolerances = 0.5mm (0.02) pin diameter ? 0.1 mm (0.004) pinout / connection pin/con. single dual 1 ac (n) ac (n) 2 ac (l) ac(l) 3 +vout +vout 4 no pin / nc no pin / nc 5 Cvout common 6 no pin / nc no pin / nc 7 nc Cvout sp ec i?cati ons can be changed wi thout noti ce! make sure you are using the latest documentation, downloadable at www.tracopower. com www .tracopower. com rev. april 21. 2015 http://www.tracopower.com


▲Up To Search▲   

 
Price & Availability of TMM40215C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X